فلاتر سحب الهواء المصنوعة من سبائك الألومنيوم
$162.61-19 Piece/Pieces
$154.46≥20Piece/Pieces
الدفع نوع: | T/T,L/C |
إنكوترم: | FOB,CFR,EXW,CIF |
نقل: | Land,Ocean,Air,Express |
ميناء: | Shenzhen,Guangzhou ,Shanghai |
$162.61-19 Piece/Pieces
$154.46≥20Piece/Pieces
الدفع نوع: | T/T,L/C |
إنكوترم: | FOB,CFR,EXW,CIF |
نقل: | Land,Ocean,Air,Express |
ميناء: | Shenzhen,Guangzhou ,Shanghai |
نموذج: YF030
علامة تجارية: يوكا
Origin: China
HS Code: 8421399090
Clapboard: Without Clapboard
Filter Number: 1
Medium Material: Fiberglass
Type: Cartridge Filter
Material: Aluminum Alloy
Housing Serve Lige: 15 Years
Filtration Performance: From 5 μm To 0.01μm
Maxi. Operate Pressure: 1.0mpa
Operate Temperature: 1.5~80ºc
Flow Rate: 1.8m³/Min
Connection: Rc3/4"
Transport Package: Brown Inner Box & Cardboard
Efficiency: F9
ACS Element Serve Life: 2000~3000 Hours
Filtration Grade: Medium Filter
Parts: Dp Indicator, Auto Drain, Sight Glass
Element Top Cap Design: Colorful To Distinguish
Diversion Fin Design On Element Top Cap: Less Pressure Loss
Resistance Corrosion: Inside And Outside
Specification: Dimension: 96 X 79x 295mm
بيع الوحدات | : | Piece/Pieces |
نوع الحزمة | : | الصندوق الداخلي وعلبة الكرتون |
مثال الصورة | : |
كيف يعمل فلتر الهواء المضغوط؟
تتطلب أنظمة الهواء المضغوط هواءً نقيًا لتعمل بشكل صحيح وتوفر الهواء للتطبيقات التي لا تضر بالآلات. تتكون فلاتر الهواء التي تعمل بشكل صحيح من مرشح مسبق وبعد فلاتر:
المرشحات المسبقة: تحبس هذه المرشحات الهواء الرطب المتسخ الذي يدخل إلى مجفف الهواء وتفلتره.
بعد الفلتر: تقوم هذه الفلاتر بترشيح هواء المجفف حيث يخرج من المجفف
تلتقط مرشحات الجسيمات الحطام والزيوت والملوثات الخشنة الأخرى. يدخل الهواء بعد ذلك إلى مرشح الالتحام ، الذي يتخلص من العناصر غير الدقيقة مثل الماء أو رذاذ الزيت. بعد أن يخرج الهواء من المجفف ، يمر عبر مرشح جسيمات آخر للتأكد من أن الهواء نظيف تمامًا.
يوصى باستخدام فلتر الهواء من سلسلة YF للصناعات في الأتمتة ومستحضرات التجميل والقولبة بالنفخ والرش وما إلى ذلك.
PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m3/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C(clearance for housing) | ||
YF010 | RC1/2" | 16.7 | 1.0 | 35.3 | 96 | 79 | 261 | 29 | 198 | 118 |
YF020 | RC3/4" | 25.0 | 1.5 | 53.0 | 96 | 79 | 261 | 29 | 198 | 118 |
YF030 | RC3/4" | 30.0 | 1.8 | 63.6 | 96 | 79 | 295 | 29 | 233 | 153 |
YF040 | RC1" | 33.3 | 2.0 | 71.0 | 96 | 79 | 295 | 29 | 233 | 153 |
YF060 | RC1" | 60.0 | 3.6 | 127.0 | 138 | 111 | 403 | 37 | 296 | 208 |
YF070 | RC1" | 83.3 | 5.0 | 177.0 | 138 | 111 | 503 | 37 | 396 | 303 |
YF080 | RC1-1/2" | 125.0 | 7.5 | 265.0 | 138 | 111 | 503 | 37 | 396 | 303 |
YF090 | RC2" | 166.7 | 10.0 | 353.1 | 174 | 142 | 736 | 58 | 607 | 469 |
YF100 | RC2-1/2" | 216.7 | 13.0 | 459.0 | 174 | 142 | 736 | 58 | 607 | 469 |
YF110 | RC2" | 283.3 | 17.0 | 600.0 | 174 | 142 | 1016 | 58 | 887 | 794 |
YF120 | RC2-1/2" | 316.7 | 19.0 | 671.0 | 174 | 142 | 1016 | 58 | 887 | 794 |
YF130 | RC3" | 416.7 | 25.0 | 883.0 | 220 | 184 | 793 | 74 | 649 | 514 |
YF140 | RC4" | 466.7 | 28.0 | 989.0 | 220 | 184 | 793 | 74 | 649 | 514 |
YF150 | RC3" | 683.3 | 41.0 | 1448.0 | 220 | 184 | 1050 | 74 | 906 | 764 |
YF160 | RC4" | 800.0 | 48.0 | 1695.0 | 220 | 184 | 1050 | 74 | 906 | 764 |
Technical requirements | Maximum operating pressure: 10 barg Operating temperature: 1.5°C~80°C. |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |